DAFNE Trouble Ticket

Home
Show
Open
Update
Close
Forward
Acknowledge
Status
Report
Logout

24hour Report

24 hour Shift Report from Thu 15 to Fri 16

Thursday 15 April report for DAY (06-14) shift

No archived data for this shift

DAFNE
e-
e+
Storing
Up
Colliding
Delivered
 
0.0 Ah
0.0 Ah
98 %
0 %
0 %
0.0
Program
Running
Logging
Efficiency
Average
Peak
Acquired
KLOE
0 %
0 %
0 %
0.0e-1
0.0e-1
0.0

Fault during the shift:

No fault recorded

Thursday 15 April report for SWING (14-22) shift

No archived data for this shift

DAFNE
e-
e+
Storing
Up
Colliding
Delivered
 
0.3 Ah
0.2 Ah
99 %
48 %
18 %
0.0
Program
Running
Logging
Efficiency
Average
Peak
Acquired
KLOE
0 %
0 %
0 %
0.0e-1
0.0e-1
0.0

Fault during the shift:

No fault recorded

Friday 16 April report for OWL (22-06) shift

No archived data for this shift

DAFNE
e-
e+
Storing
Up
Colliding
Delivered
 
0.7 Ah
0.8 Ah
99 %
99 %
37 %
0.0
Program
Running
Logging
Efficiency
Average
Peak
Acquired
KLOE
0 %
0 %
0 %
0.0e-1
0.0e-1
0.0

Fault during the shift:

03:41-03:56 WARNING POWER SUPPLY & MAGNET DIPOLE POWER SUPPLY ELECTRONICS OTHER :
DHRTT001 e' in Fault "Overtemperature" si ripristina aprendo lo sportello per far scendere la temperatura interna.
05:54-15:07 FAULT POWER SUPPLY & MAGNET QUADRUPOLE POWER SUPPLY ELECTRONICS OTHER :
QUAEL109 Trovato spento, si riaccende .

Last Warining and Fault from 6 a.m. up to now 19:59

No archived data for this shift

Fault during the shift:

08:42-08:57 FAULT POWER SUPPLY & MAGNET QUADRUPOLE POWER SUPPLY ELECTRONICS OTHER :
QUAEL 217, in sb senza segnalazioni (fascio off)
16:52-17:07 WARNING POWER SUPPLY & MAGNET DIPOLE POWER SUPPLY ELECTRONICS OTHER :
occasionalmente il dipolo dell'accumulatore va in fault per "Ps overtemperature-electronic fault-over current/voltage"

Previus report:

User info: Anonymous on
3.238.174.50