Fluence-to-Effective Dose conversion coefficients (Sv.cm2) and relative statistical uncertainties (standard deviations) for different geometrical conditions of irradiation of an anthropomorphic phantom as a function of neutron energy

(A. Ferrari, M. Pelliccioni and M. Pillon, Fluence to Effective Dose Conversion Coefficients for Neutrons up to 10 TeV, Radiat. Prot. Dos., Vol. 71, No. 3, 165-173, 1997).

Energy

(GeV)

AP

PA
LAT
ISO
2.5 E-11
8.65 E-12
1.97%
5.56 E-12
4.36%
2.31 E-12
3.24%
3.61 E-12
3.00%
1.0 E-07
1.73 E-11
3.00%
1.18 E-11
2.78%
4.98 E-12
2.14%
7.28 E-12
3.37%
1.0 E-05
3.31 E-11
3.69%
2.72 E-11
4.66%
1.09 E-11
4.79%
1.50 E-11
4.50%
1.0 E-04
4.50 E-11
1.72%
3.53 E-11
3.64%
1.34 E-11
3.64%
1.91 E-11
1.81%
1.0 E-03
2.91 E-10
2.35%
1.67 E-10
2.29%
8.48 E-11
1.85%
1.26 E-10
2.84%
1.0 E-02
5.89 E-10
2.79%
4.83 E-10
3.75%
3.40 E-10
0.86%
3.93 E-10
3.11%
3.0 E-02
3.93 E-10
3.28%
3.82 E-10
2.31%
3.07 E-10
2.80%
3.15 E-10
3.44%
5.0 E-02
4.06 E-10
2.58%
4.12 E-10
2.07%
3.45 E-10
4.82%
3.48 E-10
3.36%
1.0 E-01
4.85 E-10
3.76%
4.79 E-10
3.02%
4.04 E-10
3.77%
4.06 E-10
2.45%
2.0 E-01
4.71 E-10
4.02%
5.24 E-10
2.31%
5.61 E-10
3.34%
5.58 E-10
3.80%
5.0 E-01
5.58 E-10
1.2%
6.79 E-10
3.94%
6.63 E-10
4.56%
6.95 E-10
3.05%
1.0 E+00
7.92 E-10
2.7%
8.74 E-10
2.15%
8.92 E-10
3.85%
8.86 E-10
2.57%
2.0 E+00
9.80 E-10
3.5%
1.02 E-09
1.64%
1.15 E-09
3.50%
1.16 E-09
3.13%
5.0 E+00
1.59 E-09
0.8%
1.88 E-09
1.64%
2.16 E-09
4.77%
2.01 E-09
3.49%
1.0 E+01
2.08 E-09
1.1%
2.47 E-09
2.02%

3.05 E-09

4.39%
3.01 E-09
4.82%
5.0 E+01
2.97 E-09
3.99%
3.65 E-09
1.95%

4.85 E-09

2.67%
4.98 E-09
2.74%
1.0 E+02
3.48 E-09
4.00%
4.33 E-09
1.64%

6.45 E-09

3.31%
6.92 E-09
3.71%
1.0 E+03
6.55 E-09
1.99%
8.45 E-09
2.05%

1.43 E-08

4.35%
1.67 E-08
3.72%
1.0 E+04

1.15 E-08

3.64%
1.78 E-08
2.32%

3.31 E-08

4.31%

3.67 E-08

4.69%