#Test beam 29/01/2008, 11am ########################### * testing m1 * Position of the center of the sectors in wrt BTF gauge sector x h 0 17 13.5 1 8.5 4 2 3.2 1 3 14.9 4 4 23.5 13.5 -> Marked on the ground. -> Relative displacements to compared with nominal by Benoit. * Position of the calorimeter that monitors the beam x=46.5 h=13.5 * Begin to take data for equalization ------------------------------------- - Beam E = 471 MeV -Run 812 ; 5 min long - Start at center of sector4. - HV=1350 V -> Collected 15500 evts. -Run 813 ; 5 min long - center of sector4. - HV=1450 V -Run 813 ; 5 min long -> Collected 15500 evts. -Run 814 ; 5 min long - center of sector4. - HV=1550 V -> Collected 15600 evts. -Run 815 ; 5 min long - center of sector4. - HV=1650 V -> Collected 14400 evts. -Run 816 ; 5 min long - center of sector4. - HV=1750 V -> Collected 12200 evts. -Run 817 => aborted. -Run 818 ; 60 min long - center of sector2. - HV= 1600V -> Collected 155900 evts. -Run 819 ; 5 min long - center of sector2. - HV= 1400V -> Collected 15600 evts. -Run 820 ; 5 min long - center of sector2. - HV= 1500V -> Collected 13800 evts. -Run 821 ; 5 min long - center of sector2. - HV= 1600V -> Collected 15000 evts. -Run 822 ; 5 min long - center of sector2. - HV= 1700 V -> Collected 15100 evts. -Run 823 ; 5 min long - center of sector1 . - HV= 1650 V -> Collected 14800 evts. -Run 824 ; min long - center of sector1. - HV= 1750 V -> Collected 14800 evts. -Run 825; min long - center of sector1. - HV= 1550 V -> Collected 14900 evts. -Run 826 ; 5 min long - center of sector1. - HV= 1450 V -> Collected 15100 evts. -Run 827 aborted (beam loss) -Run 828 ; 5 min long - center of sector3. - HV= 1450 V -> Collected 15400 evts. -Run 829 ; 5 min long - center of sector3. - HV= 1550 V -> Collected evts. -Run 830 ; 5 min long - center of sector3. - HV= 1650 V -> Collected 15300 evts. -Run 831 ; 5 min long - center of sector3. - HV= 1350V (really 1350 !) -> Collected 15100 evts. -Run 832 ; 5 min long - center of sector0. - HV= 1350V -> Collected 14900 evts. -Run 833 ; 5 min long - center of sector0. - HV= 1450 V -> Collected 1400 evts. -Run 834 ; 5 min long - center of sector0. - HV= 1550 V -> Collected 14500 evts. -Run 835 ; 5 min long - center of sector0. - HV= 1650 V -> Collected 15900 evts. -Run 836: test to know which "Labeled" HV is plugged in which sector : "labeled"s0 set to 0. => RES: Labeled HV 0 is really in sector 0 -Run 837: test to know which "Labeled" HV is plugged in which sector : "labeled"s4 set to 0. => RES: Labeled HV 4 is really in sector 4 -Run 838: test to know which "Labeled" HV is plugged in which sector : "labeled"s3 set to 0. => RES: Labeled HV 3 is really in sector 3 -Run 839: test to know which "Labeled" HV is plugged in which sector : "labeled"s1 set to 0. => RES: Labeled HV 1 is really in sector1 -Run 840: test to know which "Labeled" HV is plugged in which sector : "labeled"s set to . => RES: Labeled HV 2 is really in sector2 **** We set the HV to those figured out by Paolo: s0 1668 s1 1602 s2 1631 s3 1496 s4 1600 -Run 841 First point of the scan, night long run. x=10 on scale 2 (that of sector 3) h=10.44 -Run 842 Energy scan sector2 (centre) hv =1631 energy = 471.2 -Run843 eneergy 424.1 -Run844 energy 377. While we were taking run 846, changed the HV to gain in dynamic: s0 1751 s1 1682 s2 1712 s3 1570 s4 1680 -run 847, single electron 471 MeV -run 848, single electron 448 MeV, 8900 evts -run 849, sgle ele 424 MeV, 10600 evts -run 850, same, 20 kEvts -run 851, 400 MeV, 14 kEvt -run 852, 377 MeV, 15 kEvt -run 853, 340 MeV, 13400 kEvt -run 854, 283 MeV, 15200 kEvt -run 855, 236 MeV, kEvt => Dirty run, too many ele Redone in next run. -run 856, 236 MeV, kEvt -run , MeV, kEvt -run 858 -> to be forgotten # Begin the scan of the surface of m1 ====================================== E= 471 MeV HV unchanged Sgle ele 5 minutes runs. Below, when x<0, means on the side of sector 0. * Run 859 s0 -(x,h)=-9.75, 15.75 15 kEvts * Run 860 s0 -(x,h)=-7.25, 15.75 11200 evts * Run 861 s0 -(x,h)=-12.75, 15.75 15200 evt * Run 862 s4 -(x,h)=15.4, 15.75 * Run 863 s4 -(x,h)=12.86 , 15.75 14500 evts * Run 864 s4 -(x,h)=18.36, 15.75 15600 evts * Run 865 s0 -(x,h)=-13.45 , 10.44 15700 evts Very strange ! should be in s0, and seems to be in fact in s1 * Run 866 -(x,h)=-18.75, 10.44 14300 Evts Again strange: supposed to be in s0 , and just a bit in s1. * Run 867 -(x,h)=-24, 10.44 15100 Very strange, same symptoms as above... The problem with the 3 previous runs should ne due to a too high intensity (more than one electron at a time)... VERTICAL SCAN * Run 868 s2 -(x,h)=2.8 , -0.5 Stopped shortly after start. Same problem as above... Linac in electron mode might be the reason?? PB solved a few minutes later, resume vertical scan * Run 871 -(x,h)=2.8 , -0.5 12000 evts * Run 872 -(x,h)=2.8 , 1 14300 evts * Run 873 -(x,h)=2.8 , 3.5 13600 evts * Run 874 -(x,h)= 2.8, 6 12200 evts * Run 875 -(x,h)= 2.8, 8.5 13000 -> The above taught us that adc3 = sector 4 adc5 = 2 adc2 = 1 adc4 = 3 adc0 = 0