Summary of NOT INSTALLED chambers. Il numero di spare per tipo di camera al momento disponibile e' in rosso, grassetto Il numero in blu grassetto fra parentesi indica le camere che possono essere ancora recuperate (da recuperare ad es. gas leak...) Il numero in ciano, grassetto indica le camere che ancora devono essere testate e che al momento sono considerate GOOD!
25 M5R4: [6 Good, 19 Bad, Needed for Installation: 5] Spare: 1 (+10) In piu' rispetto al conto a FI ci sono 2 camere sbudellate: recupero pannelli? 11 M5R3: [5 Good, 4 Spare, 2 Bad] Spare: 9 (+2) 11 M5R2: [1 Good, 2 Spare, 8 Bad] Spare: 3 (+3) 5 M4R3: [4 Good, 1 Bad, Needed for Installation: 3] Spare: 1 (4 TbT) In più, rispetto al conto fatto sopra, ci sono 2 'bigap' nel container (capGS): possono essere usate per comporre una camera? 5 M4R2: [2 Good, 3 Bad] Spare: 2 34 M3R3: [29 Good, 5 Bad, Needed for installation: 24] Spare: 5 (+1) (6 TbT) 43 M2R3: [27 Good, 16 Bad, Needed for installation: 24] Spare: 3 (8 TbT)
For details, see below: BAD Chambers not recoverable are in RED (bold) Chambers that can be maybe recovered with some work are in BLUE (bold)
Status M5R4. [6G, 19B, Ins: -5] 25 tot. Spare: 1(+10) 6 good. L34,L23 Roma1 (GOOD) L33,L41,F57,F79 Roma2 (GOOD) 2 bad @ LNF camera pulita L35,L66 -> in camera pulita. Gas leak problems. 4 bad @ FI F123,F87: gas leak F38,F100: to be opened. Probably can be used to make 1 good chamber. 4 bad @ LNF gapGS F03: bad to be destroyed F48,F60,F70,F132: high currents (loose guard wires??) 9 bad @ 156 F131: HV gap B short. F124: Loose wires or bubble F41: Loose wires or bubble F06: Loose wires L49: High dark current (80nA). Strange structure on TestC counting rate. F05, F51, F52, F130: small discharges. Test C high counts Mario believes that there are loose guard wires or (worse) loose wires inside the chamber.
Status M5R3. [5G, 4S, 2B] 11 tot. Spare: 9(+2) 5 good 4 chambers good @ 156 L37 Roma1 (GOOD) 4 spares @ 156 (minor problems) L07,L20,L51 (bad gain uniformity) L09 (high counting rate) 1 bad @ LNF camera pulita L55 gas problem: inside clean room to be sealed. (marked as 57: is wrong!) 1 bad @ FI L06 gas leak problem: To be sealed.
Status M5R2. [1G 8B 2S] 11 tot. Spare: 3(+3) 1 good 1 good chambers @ 156 3 bad @ FE F17 (broken wire), F22-F24 (piste tranciate) 2 bad @ LNF capGS F01 high current @ 2.7kV F18 chemical gold. Bad gain uniformity. 3 bad @ 156 F14: large dead zone F26: broken wire F33: gap A trips @ 500V 1 spare @ LNF capGS F34: waiting to be dressed. Bad Gas Gain test 1 spare @ 156 F35: bad test C uniformity
Status M4R3. [4G, 1B, Ins: -3] 5 tot. Spare: 1 (4 TbT) 4 good chambers @ LNF capGS F02,F21,F42,F47: waiting to be tested 1 bad @ LNF capGS F39: serious gas, electronics / HV problems
Status M4R2. [2G, 3B] 5 tot. Spare: 2 2 good F02 Roma2 F03 Roma1 1 bad @ 156 F06. High current @ 2.2kV 2 bad @ FE F15,F26 : bad HV (bubble or loose wire)
Status M3R3. [29G, 5B, Ins: -24] 34 tot. Spare: 5(+1) (6 TbT) 29 good 28 @ 156 [21 ready for installation] 6 to be tested @ 156 L012 @ Roma1 5 bad @ LNF L03: gas exploded [currently in ex tubificio] L25: broken wire (@ CA?) L44: [currently in ex tubificio]: Problem under investigation L55: cut in 2 pieces in clean room L56: broken wire [clean room] Chambers 25 and 44 need to be looked at in more detail (where is 25? what is the problem of 44?)
Status M2R3. [26G , 17B, Ins: -24] 43 tot Spare: 2 (8 TbT) 26 good 18 @156 [18 chamber read for inst] 8 to be tested @ 156 2 bad @ 156 F51 (gap A unstable @ 2.6 kHv) F20 (bubble) 1 bad @ capGS F35: bubble. dead 14 bad @ FE All dead |
|