GILDA Italian Proposal II Semester 2009

Beam-time allocation

Proposal

Number

Title

Proposer

Requested

Shifts

Assigned

Shifts

Comments

Schedule

08-01-840

Quantitative determination of Fe coordination and oxidation species in silicate melts

Poe

15

9

La Commissione ritiene sufficienti 9 shifts per le misure XANES proposte.

 

08-01-841

Local structure study on CoPt alloys with perpendicular magnetic anisotropy

Liscio

18

18

 

 

08-01-842

Erbium local environment in proton ion-exchanged glass: an EXAFS study

Gonella

12

0

La proposta ha ottenuto tempo macchina da ESRF su GILDA con il numero MA-815

 

08-01-844

Local structure and ageing of resin supported nanosized clusters of 3d metals

Meneghini

15

12

 

 

08-01-845

CoPt/NiO exchange bias interface studied by XAS

Agostinelli

18

0

La Commissione non valuta la proposta perchè è inglobata nella 08-01-852

 

08-01-846

Local structure of Pd clusters decorating Mg nanoparticles for hydrogen storage

Pasquini

12

0

La proposta ha ottenuto tempo macchina su GILDA da ESRF con il numero CH-2948

 

08-01-847

Where do the holes reside in (Ga,Fe)N doped with Mg?

Rovezzi

18

0

La proposta ha ottenuto tempo macchina su GILDA da ESRF con il numero HS-3919

 

08-01-848

Valence state and redox properties of Fe in quartz

Di Benedetto

15

9

Problematica molto interessante; la proposta non è suffientemente chiara rispetto agli obiettivi dell’esperimento specifico proposto, a parte l’individuazione dello stato di ossidazione +4 del ferro. La Commissione suggerisce di concentrare l’attenzione su questo aspetto.

 

08-01-849

X-ray absorption spectroscopic study of contaminating arsenic in soils around the Argentina Andes volcanic area (JuJuy Province, Northern Argentina)

Petrini

12

12

La Commissione assegna tempo macchina sub-judice alla caratterizzazione chimica e mineralogica dei campioni.

 

08-01-851

Local structure study on Ba-site substituted layered cobaltites

Bardelli

9

0

La proposta non chiarisce quali informazioni sulla struttura magnetica si possano ottenere dalle misure; inoltre non è chiaro come si possano ottenere informazioni sulla sostituzione del Ba da parte dello Sr e del Ca, da misure eseguite solo sul Co.

 

08-01-852

Study of interface properties of Co50M50/NiO (M = Pt,Fe) multilayers by XAS

Testa

18

18

Proposta molto interessante; la Commissione suggerisce ai proponenti di eseguire lo studio completo su tutti i campioni e sulle due polarizzazioni su uno dei due sistemi proposti, prima di, eventualmente, studiare il secondo.

 

08-01-853

In situ reduction of Se adsorbed on montmorillonites by means of hydrogen gas

Bardelli

15

12

 

 

08-01-854

EXAFS experiment to investigate the effect of the Ag site on the refractive index of Ag-doped glass waveguides

Maurizio

15

12

 

 

08-01-855

Diamond solid state ionization chambers for x-ray absorption spectroscopy applications

De Sio

 

18

 

 

08-01-856

XAS characterization of magnetic Ag nanoparticles

Comaschi

12

12

 

 

08-01-857

Evolution under thermal annealing of the local order around Yb3+ ions in preforms of optic fibers

D’Acapito

9

9

 

 

08-01-858

Local order around Er in new Er-Y silicate materials for optical amplification. An EXAFS study.

D’Acapito

18

0

La Commissione giudica l’esperimento utile per acquisire ulteriori informazioni sul fenomeno della luminescenza dell’ Er.
Non assegna tempo macchina per mancaza dello stesso.

 

08-01-859

XAS characterization of the metal binding sites in KmtR and NmtR bacterial repressor proteins

Mangani

9

0

La proposta presenta una problematica scientificamente molto interessante. La Commissione ha qualche dubbio sulla identificabilità dei leganti da dati EXAFS in assenza di strutture cristallografiche di bassa risoluzione. Suggerisce di chiarire questo aspetto prima di risottomettere la proposta.

 

08-01-860

IDENTIFICATION OF CHROMOPHORE IONS IN GLASS MOSAIC TESSERAE

Molin

9

9

 

 

08-02-654

PREHISTORIC PYROTECHNOLOGY: INSIGHTS ON HOMININ BEHAVIOR FROM HIGH RESOLUTION STUDY OF COMBUSTION FEATURES

BERNA

12

3

La Commissione ritiene la problematica molto interessante. Gilda che dispone di un Image Plate e non di una CCD non sembra essere la beamline migliore per l’esperimento, soprattutto per la lettura non in linea dell’ IP. Inoltre la dimensione del fascio richiesta è inferiore a quella minima disponibile di un fattore 3-4. Si assegnano 3 shifts per lo studio di fattibiltà e per valutare bene il tempo necessario per l’esperimento.