MINUTE MEETING SERVIZI IN PIT E COUNTING ROOM 20.6.96 @LNF ========================================================== PRESENTI: S.BIANCO, D.CALVO, V.LUCHERINI, S.SARWAR PIT ----- POTENZA AC: PANNELLO PRINCIPALE DI DISTRIBUZIONE (P) COLLOCATO A DX COLONNA STRUTTURA PORTACAVI, PARETE DEL PIT. ALTRI DUE PANNELLI SECONDARI (S1, S2) SULLA PARETE DX E SX PER UTENZE MODESTE (TOOLS, ETC). ALIMENTATORE MAGNETE: COLLOCATO SUL LATO DX DEL PIT, VICINO ANGOLO INTERNO MACCHINA. DA P1 AD ALIMENTATORE LINEA DI POTENZA FISSA CHE CORRE SULLA PARETE PIT. DA ALIMENTATORE LINEE FISSE CORRONO DI NUOVO SULLA PARETE PIT, SALGONO SULLA COLONNA , VIAGGIANO SULLA TRAVE E SCENDONO SUL MAGNETE. DURANTE GLI SPOSTAMENTI DAL FASCIO LE LINEE VENGONO DISCONNESSE, PROLUNGATE E RICONNESSE NELLA NUOVA POSIZIONE A CENTRO BUCA. SB VALUTERA' LA LUNGHEZZA NECESSARIA PER LINEE PRINCIPALI E PROLUNGHE. ALIMENTAZIONE RACK FEE, VALVOLE, MOVIMENTAZIONI: DA P1 SU PER COLONNA, TRAVE, DENTRO SISTEMA PORTACAVI RUOTANTE. SEGUONO STESSO ROUTING CAVI SEGNALI. SERVE OTTIMA SCHERMATURA PER ALIMENTAZIONI FEE. ACQUA RAFFREDDAMENTO RACK FEE: USCITA VICINO P1, RAGGIUNGE MAGNETE SU PASSERELLA (PONTE LEVATOIO) DA BORDO BUCA. IN CASO DI SPOSTAMENTO VIENE DISCONNESSA E SMONTATA. DC COMUNICA PORTATA NECESSARIA DA CALCOLI LUIGI BUSSO: 200 L/H/KW. SB COMUNICA CHE LA TEMPERATURA STANDARD ACQUA RAFFREDDAMENTO E' 32C. DC CONTROLLERA' CON L.BUSSO LA TEMPERATURA RAGGIUNGIBILE CON TALE ACQUA. ARIA COMPRESSA: VICINO P1 E DUE USCITE AUSILIARIE S1 ED S2. POI CORRE SU COLONNA E DENTRO SISTEMA PORTACAVI. GAS: LINEA ACCIAIO ATTRAVERSO BUCHI NEL MURO, LUNGO PARETE DAFNE, SULLA TRAVE PORTACAVI. PRIMA DI ENTRARE NELLA CATENA, CONNESSIONE ACCIAIO-RILSAN. POI DENTRO CATENA PORTACAVI. SS COMUNICHERA' MINIMO DIAMETRO NECESSARIO PER TUBI DI RILSAN NELLA CATENA, E SB VERIFICHERA' SPAZIO. ACQUA RAFFREDDAMENTO MAGNETE: USCITA VICINO P1, VERSO ALIMENTATORE. COUNTING ROOM --------------- ARIA COMPRESSA: UNA SOLA PRESA PER USI VARI ACQUA RAFFREDDAMENTO RACK: NON NECESSARIA (L.BUSSO CONFERMARE) ACQUA POTABILE: NELLA SALA TERMINALI RACK ELETTRONICA: N.10 DI FRONTE PARETE DAFNE, VICINO USCITA CAVI, ALTRI N.1 LUNGO PARETE OPPOSTA (ESTERNA, A DELIMITARE CORRIDOIO). CONSOLE DI COMANDO IN DUE POSIZIONI ALTERNATIVE, COMUNQUE IN AREA (PICCOLA) ISOLABILE TERMICAMENTE ED ACUSTICAMENTE DA RACK ELETTRONICA TRAMITE TRAMEZZI SOFT. DIVISORIO SALA TERMINALI-ELETTRONICA SENZA PORTA. POTENZA AC RACK ELETTRONICA: BLINDOSBARRE SU PARETE SOPRA LE DUE FILE DI RACK. (MINUTE PRESE DA SB)